Brand1
In Stock
01422
0.0
Out of stock
10900 
GSM modem frequencies: 850 / 900 / 1800 / 1900 MHz Power supply: 12-36 V DC or 12-24 V AC Current usage: Standby – 50 mA While sending SMS – instantly up to 0,25 A Number of relays: 2 Relay commutated: DC or AC up to 24 V, current up to 1 A Relay control: command By phone call, SMS or DTMF tones Switching relay contacts: Pulse – control command commutates relays for 1-60 sec. Level – control command commutates relays until the next control command, e.g., until the next call. Memory: Up to 8 administrator names and their phone numbers Up to 1000 user names and their phone numbers Inputs: 2 (IN1 and IN2), Set for NO (R ≥ 10 kΩ) or NC (R ≤ 0,5 kΩ)type circuits  Operating environment: Air temperature from -20 C to +50 C, at humidity up to 93% (without condensation) Parameter setting: a) Software "TrikdisConfig" via USB; b) Special syntax SMS messages Controller dimensions andweight: 100.6 x 80.7 x 23.5 mm , up to 110g
01421
0.0
In stock
11500 
+
Power supply AC 16–18 V or DC 16 – 24 V Power consumption (only module) 80 mA idle running Up to 150 mA within transmitting Backup power supply 12 V / 7 Ah battery Battery charging current 0,1-2,0 A Power supply for connected security devices Direct 13.6 V voltage between [AUX+] and [COM] contacts, current up to 1.1 A GSM modem SIM900 specification GSM EGSM 900 MHz and DCS 1800 MHz Power failure thresholds Alternating power supply is lost/restored Voltage of the battery has dropped to 11,5 V Voltage of the battery has restored to 12,6 V ZN terminals (inputs) 8 programmable; selectable NC, NO or EOL=2,2 kΩ type; Expandable to up to 32 inputs with input expansion modules CZ8 Various expansion modules Up to 14, including keypads PGM terminals (outputs) 4, NO type terminals of the field-effect transistor, able to commutate up to 30 V / 1.5 A between COM terminal Control codes Up to 40 Entry Delay and Exit Delay times 0-255 seconds Siren duration 0–9999 seconds Communication protocols TCP/IP or UDP/IP over GPRS; SMS Encoding of messages Contact ID protocol codes SMS messages to users Customized text to 5 mobile phones, according to selected event types Calls to the user To 2 mobile phones, according to selected event types Operating environment From -10 C to 50 C when relative air humidity is 80 % at +20 C Dimensions 103 x 71 x 33,5 mm 
01419
0.0
Out of stock
12900 
Power supply voltage DC 10…16 V Used current 60–100 mA (stand-by), Up to 250 mA (transmitting) GSM modem frequency 850 / 900 / 1800 MHz Memory Up to 60 messages Inputs 2, NC type Output 1 OC type, commutating up to 30 V voltage and current up to 1 A Setting configuration via the USB port Operating environment From -10 °C to 50 °C, with relative air humidity 80% when +20 °C Dimensions 65 x 79 x 25 mm
05807
0.0
In stock
11500 
+
Power supply voltage DC 12,6 ± 3 V Current consumption 120 mA (stand-by) Up to 250 mA (transmitting) Ethernet connection IEEE802.3, 10 Base-T, RJ45 socket Data pack content Contact ID format codes Memory Up to 100 messages Inputs 2, NC/NO/EOL-2,2 kΩ type (4 – E10C) Output 1 OC type, commutating voltage up to 30 V and current up to 500 mA Configuration Through the USB port with software Econfig Operating environment From -10 °C to 50 °C, with relative air humidity 80% when +20 °C
07578
0.0
In stock
7700 
+
+12V power supply terminal Common ground terminal Synchronizing signal terminal Data signal terminal 1st input terminal for connection of external circuits (type NC/NO/EOL=2.2 kΩ can be set) Output terminal (OC type) 2nd input terminal for connection of external circuits (type NC/NO/EOL=2.2 kΩ can be set)
05804
0.0
In stock
12400 
+
• GPRS, CSD or SMS channels can be used to transmit alarm signals to the Signal Receiving Center. • To increase the probability of successful message delivery, the G10 can transmit using the primary GSM communication channel and in case of failure, the secondary GSM channel can be used • Compatible with DSC, Paradox, Pyronix, Caddx boards • Alarm signals are transmitted using Ademco Contact ID protocol codes • In addition G10 can convert any alarm event into text and send SMS to 1-4 Phone numbers • Supports English, Lithuanian, Estonian, Turkish, Greek, and Russian SMS Character Encoding New! • PGM Output switching via SMS • Remote Setup and Upgrade • Two levels of access to access the settings • Laser-engraved aluminum packaging 
05805
0.0
In stock
12400 
+
TRIKDIS GSM/GPRS Alarm signal transmitter G10T, programmer, Universal The G10 is the communication device used to transmit alarm messages from the security system panel to a receiving center via GSM. Compatible with the telephone communication device of the system panel. security The messages in the KLS can be transmitted through the GPRS connection, through a DTMF call or through SMS messages To increase the probability of successful message delivery, the G10 can transmit using the primary GSM communication channel and in case of failure, the secondary GSM channel can be used Even if GPRS communication with both servers is lost, information can be sent via SMS Alarm signals are transmitted using Ademco Contact ID protocol codes G10T can convert any alarm event into text and send SMS to 1-4 phone numbers Supports English, Lithuanian, Estonian, Turkish, Greek, and Russian SMS Character Encoding New! Remote Setup and Upgrade Two levels of access to access the settings Laser engraved aluminum packaging
01418
0.0
In stock
13500 
+
8 zones (possibility to expand to 32); 9 zone functions; Exclusive zone for two-wire smoke etector; 8 partitions; Internal clock; Control of temperature sensors; Tamper tracking; Convenient default settings for fast installation of the security system.
01420
0.0
In stock
11500 
+
The main board has six inputs, which number can be expanded up to 32. Up to 16 various expansion modules can be connected. Inputs can be partitioned to 8 independent groups; Every input can be described as an On/Off, Delay, Interior, Interior STAY, Instant, Instant STAY, 24 hours, Fire or Silent zone; The security system can be armed/disarmed with a code keypad, telephone call or by breaking the circuit of input ON/OFF; Possible arming modes are ARM/STAY/OFF; Automatic arming of the system (AutoARM), sound signal indicating the security system arming/disarming (Bell Squawk) and temporary bypass a zone (BYPASS) functions are presented; Six programmable (PGM) outputs. These operating options can be assigned to every output: Buzzer, State, Read, Flash, Bell, AC OK, Battery OK, Remote Control by SMS or Remote Control by DIAL. When Remote Control by SMS or Remote Control by DIAL operating mode is assigned, output state can be controlled remotely with an SMS message or with a telephone call;
Product filters
Brand (1)
In Stock