Fire Alarm Systems

Brand1
Detector Type
Device Type
In Stock
Loop Number
Price
09504
0.0
In stock
1,78100 
+
Addressable fire alarm control panel with 1 loop. Up to of 100 addresses (detectors, modules, sounders or manual call points) with the loop. Self-search and self-diagnosis functions. 250 programmable zones, 20 alarm and fault led display zones, 6.000 event history logs, free configuration and maintenance software, configuration via USB port, 2 supervised sounder outputs and 2 configurable relay outputs. Graphic LCD display. Auxiliary output of 24V 500 mA. ABS plastic casing for wall mounting and even prepared to be embedded into it. Multilingual keyboard. Able to be networked (F-Network or S-Network) up to 32 control panels o repeaters via RS485 or fiber optics. Modbus output for integrations and Contact ID for connection to CMS (optional). Full remote access of the panel if a TED-151-CL card (Detnov Cloud) is added. CPR certificate EN 54-2, EN 54-4. Requires 2 BTD-1207 batteries not included. Dimensions: 430 x 268 x 109 mm.
Device TypeControl Panel Fire Alarm System TypeAddressable System
09616
0.0
In stock
1,64700 
+
Addressable fire alarm control panel with 1 loop. Up to of 100 addresses (detectors, modules, sounders or manual call points) with the loop. Self-search and self-diagnosis functions. 250 programmable zones, 20 alarm and fault led display zones, 6.000 event history logs, free configuration and maintenance software, configuration via USB port, 2 supervised sounder outputs and 2 configurable relay outputs. Graphic LCD display. Auxiliary output of 24V 500 mA. ABS plastic casing for wall mounting and even prepared to be embedded into it. Multilingual keyboard. Able to be networked (F-Network or S-Network) up to 32 control panels o repeaters via RS485 or fiber optics. Modbus output for integrations and Contact ID for connection to CMS (optional). Full remote access of the panel if a TED-151-CL card (Detnov Cloud) is added. CPR certificate EN 54-2, EN 54-4. Requires 2 BTD-1207 batteries not included. Dimensions: 430 x 268 x 109 mm.
Device TypeControl Panel Fire Alarm System TypeAddressable System
09617
0.0
In stock
2,27700 
+
Addressable fire alarm control panel with 2 loops. Up to of 500 addresses (detectors, modules, sounders or manual call points) with the loop. Self-search and self-diagnosis functions. 250 programmable zones, 20 alarm and fault led display zones, 6.000 event history logs, free configuration and maintenance software, configuration via USB port, 2 supervised sounder outputs and 2 configurable relay outputs. Graphic LCD display. Auxiliary output of 24V 500 mA. ABS plastic casing for wall mounting and even prepared to be embedded into it. Multilingual keyboard. Able to be networked (F-Network or S-Network) up to 32 control panels o repeaters via RS485 or fiber optics. Modbus output for integrations and Contact ID for connection to CMS (optional). Full remote access of the panel if a TED-151-CL card (Detnov Cloud) is added. CPR certificate EN54-2, EN54-4 and EN54-13. Requires 2 BTD-1207 batteries not included. Dimensions: 430 x 268 x 109 mm.
ColorBlack Device TypeControl Panel
09816
0.0
In stock
3,30200 
+
Addressable fire alarm control panel with 4 loops. Up to of 1.000 addresses (250 addresses per loop: detectors, modules, sounders or manual call points). Self-search and self-diagnosis functions. 250 programmable zones, 6.000 event history logs, free configuration and maintenance software, configuration via USB port, 2 supervised sounder outputs and 2 configurable relay outputs. Graphic LCD display. Auxiliary output of 24V 500mA. Metal box. Multilingual keyboard. Able to be networked (F-Network or S-Network) up to 32 control panels o repeaters via RS485 or fiber optics. Modbus output for integrations and Contact ID for connection to CMS (optional). Full remote access of the panel if a TED-151-CL card (Detnov Cloud) is added. CPR certificate EN54-2, EN54-4 and EN54-13. Requires 2 BTD-1207 batteries not included. Dimensions: 430 x 360 x 120 mm
ColorBlack Device TypeControl Panel
10385
0.0
In stock
9300 
+
Abort manual call point. Color blue. With test key, surface mount. Protective plastic cover included. Indoor use. Includes resistance of 100 Ohm -2W. Dimensions: 98 x 98 x 48 mm.
ColorBlue Device TypeCall Point
09510
0.0
Out of stock
28400 
Addressable loop sounder with beacon and built-in isolator. Low power consumption. 32 tones and 3 configurable volumes (Low, Medium, High). Acoustic power 76 dBA to 117 dBA depending on the selected tone. It takes just one address in the loop. Red color. IP33C. Deep base. CPR certificate EN 54-3 and EN 54-17. Dimensions: 100 x 75 mm
ColorRed Device TypeSounder
10433
0.0
In stock
15600 
+
Addressable monitor and control module with built-in isolator of 1 supervised technical input for the status signaling of equipment that provides NC or NO contact and 1 voltage-free relay output providing C, NO, NC contact. It takes two loop addresses. Direct feed from the loop. LED status indicators. Connection through removable strips up to 2.5mm2 section. Possibility of being installed in DIN rail or flat to wall mounting in box BOX-ONE. Consumption less than 300μA at rest. Red color. Dimensions: 100 x 82 x 23 mm. CPR certificate EN54-18 and EN54-17.
ColorRed Device TypeModular
09794
0.0
In stock
23000 
+
Addressable monitor and control module with built-in isolator of 2 supervised technical inputs for the status signaling of equipment that provide NC or NO contact and 2 voltage-free relay outputs providing two C, NO, NC contacts. It occupies four directions in the loop. Direct feed from the loop. LED status indicators. Connection through removable strips up to 2.5mm2 section. Possibility of being installed in DIN rail or flat to wall mounting in box BOX-ONE. Consumption less than 300μA at rest. Red color. Dimensions: 100 x 82 x 23 mm. CPR certificate EN54-18 and EN54-17.
ColorRed Device TypeModular
15361
0.0
Out of stock
88500 
Hand-held programmer for 200A addressable detectors range and 400 series devices (modules, call points and sounders). Allows the display of the device address, analogue value of the detectors and consecutive address programming. Includes 4 AA batteries.
ColorWhite Device TypeProgrammer
15309
0.0
In stock
14200 
+
Addressable manual call point with built-in isolator. LED status indicator and test key. Red color. CPR certificates EN54-11 and EN54-17. Dimensions: 85 x 85 x 55 mm.
ColorRed Device TypeCall Point
09507
0.0
Out of stock
7800 
Addressable heat (58°C fixed temperature and thermal rate of rise) detector with built-in isolator, with algorithm verification. Led status indicator and output for remote pilot indicator PAD-10 or buzzer BUD-200. White color. Requires base Z-200 or Z-200-H. Anti-theft system (only with Z-200). CPR certificate EN 54-5 and EN 54-17. Dimensions: 100 x 40 mm.
ColorWhite Device TypeDetector
09571
0.0
In stock
11400 
+
Addressable heat (58°C fixed temperature and thermal rate of rise) detector, with algorithm verification. Led status indicator and output for remote pilot indicator PAD-10 or buzzer BUD-200. Black color. Allows installation without polarity. Requires base Z-200-B or Z-200-B-H. Anti-theft system (only with Z-200). CPR certificate EN 54-5. Dimensions: 100 x 40 mm.
ColorBlack Device TypeDetector
11430
0.0
In stock
11200 
+
Addressable heat (58°C fixed temperature and thermal rate of rise) detector with built-in isolator, with algorithm verification. Led status indicator and output for remote pilot indicator PAD-10 or buzzer BUD-200. White color. Requires base Z-200 or Z-200-H. Anti-theft system (only with Z-200). CPR certificate EN 54-5 and EN 54-17. Dimensions: 100 x 40 mm.
ColorWhite Device TypeDetector
09503
0.0
In stock
10800 
+
Addressable optical & heat detector with built-in isolator, with dirt compensation and algorithm verification. Led status indicator and output for remote pilot indicator PAD-10 or buzzer BUD-200. White color. Requires connection base Z-200 or Z-200-H. Anti-theft system (only with Z-200). CPR certificates EN 54-5, EN 54-7 and EN 54-17. Dimensions: 100 x 40 mm.
ColorWhite Device TypeDetector
09835
0.0
In stock
11900 
+
Addressable optical & heat detector with built-in isolator, with dirt compensation and algorithm verification. Led status indicator and output for remote pilot indicator PAD-10 or buzzer BUD-200. White color. Requires connection base Z-200 or Z-200-H. Anti-theft system (only with Z-200). CPR certificates EN 54-5, EN 54-7 and EN 54-17. Dimensions: 100 x 40 mm.
ColorWhite Device TypeDetector
10371
0.0
In stock
8900 
+
Addressable high temperature detector (fixed at 78ºC) with built-in isolator, with algorithm verification. Led status indicator and output for remote pilot indicator PAD-10 or buzzer BUD-200. White color. Requires connection base Z-200 or Z-200-H. Anti-theft system (only with Z-200). CPR certificate EN 54-5 and EN 54-17. Dimensions: 100 x 40 mm.
ColorWhite Device TypeDetector
11431
0.0
Out of stock
9700 
Addressable high temperature detector (fixed at 78ºC) with built-in isolator, with algorithm verification. Led status indicator and output for remote pilot indicator PAD-10 or buzzer BUD-200. White color. Requires connection base Z-200 or Z-200-H. Anti-theft system (only with Z-200). CPR certificate EN 54-5 and EN 54-17. Dimensions: 100 x 40 mm.
ColorWhite Device TypeDetector
09509
0.0
In stock
14900 
+
Addressable manual call point with built-in isolator. LED status indicator and test key. Red color. CPR certificates EN54-11 and EN54-17. Dimensions: 98 x 98 x 48 mm.
ColorRed Device TypeCall Point
10386
0.0
In stock
16400 
+
Addressable control module for 1 relay output, provides one contact C, NO, NC. It takes one address in the loop. Fed directly from the loop. LED status indicator. Connection through removable strips up to 2.5mm2 section. Possibility of being installed in DIN rail or flat to wall mounting in box BOX-ONE. Consumption less than 300μA at rest. Non polarity installation. Red color. Dimensions: 100 x 82 x 23 mm. CPR certificate EN54-18.
ColorRed Device TypeModular
13760
0.0
In stock
22700 
+
Addressable monitor module of 1 conventional zone, allows connection of up to 20 conventional detectors and / or 32 conventional manual call points. Can identify between detector alarm and push button, between the fault by cutting or by short circuit in the zone. It takes one loop address. Requires 24 Vdc auxiliary power. LED status indicator. Connection through removable strips up to 2.5mm2 section. Possibility of being installed in DIN rail or flat to wall mounting in box BOX-ONE. Consumption less than 300μA at rest. Allows installation without polarity. Red color. Dimensions: 100 x 82 x 23 mm. CPR certificate EN54-18.
ColorRed Device TypeModular
Show another 20 products