09504
1 LOOP ADDRESSABLE CONTROL PANEL CAD-150-1
0.0
In stock
1,781
00
₾
Add to cart
+
−
Addressable fire alarm control panel with 1 loop. Up to of 100 addresses (detectors, modules, sounders or manual call points) with the loop. Self-search and self-diagnosis functions. 250 programmable zones, 20 alarm and fault led display zones, 6.000 event history logs, free configuration and maintenance software, configuration via USB port, 2 supervised sounder outputs and 2 configurable relay outputs. Graphic LCD display. Auxiliary output of 24V 500 mA. ABS plastic casing for wall mounting and even prepared to be embedded into it. Multilingual keyboard. Able to be networked (F-Network or S-Network) up to 32 control panels o repeaters via RS485 or fiber optics. Modbus output for integrations and Contact ID for connection to CMS (optional). Full remote access of the panel if a TED-151-CL card (Detnov Cloud) is added. CPR certificate EN 54-2, EN 54-4. Requires 2 BTD-1207 batteries not included. Dimensions: 430 x 268 x 109 mm.
Device Type
Control Panel
Fire Alarm System Type
Addressable System
CODE:
09616
1 LOOP ADDRESSABLE CONTROL PANEL CAD-150-1 MINI
0.0
In stock
1,647
00
₾
Add to cart
+
−
Addressable fire alarm control panel with 1 loop. Up to of 100 addresses (detectors, modules, sounders or manual call points) with the loop. Self-search and self-diagnosis functions. 250 programmable zones, 20 alarm and fault led display zones, 6.000 event history logs, free configuration and maintenance software, configuration via USB port, 2 supervised sounder outputs and 2 configurable relay outputs. Graphic LCD display. Auxiliary output of 24V 500 mA. ABS plastic casing for wall mounting and even prepared to be embedded into it. Multilingual keyboard. Able to be networked (F-Network or S-Network) up to 32 control panels o repeaters via RS485 or fiber optics. Modbus output for integrations and Contact ID for connection to CMS (optional). Full remote access of the panel if a TED-151-CL card (Detnov Cloud) is added. CPR certificate EN 54-2, EN 54-4. Requires 2 BTD-1207 batteries not included. Dimensions: 430 x 268 x 109 mm.
Device Type
Control Panel
Fire Alarm System Type
Addressable System
CODE:
09617
2 LOOP ADDRESSABLE CONTROL PANEL CAD-150-2
0.0
In stock
2,277
00
₾
Add to cart
+
−
Addressable fire alarm control panel with 2 loops. Up to of 500 addresses (detectors, modules, sounders or manual call points) with the loop. Self-search and self-diagnosis functions. 250 programmable zones, 20 alarm and fault led display zones, 6.000 event history logs, free configuration and maintenance software, configuration via USB port, 2 supervised sounder outputs and 2 configurable relay outputs. Graphic LCD display. Auxiliary output of 24V 500 mA. ABS plastic casing for wall mounting and even prepared to be embedded into it. Multilingual keyboard. Able to be networked (F-Network or S-Network) up to 32 control panels o repeaters via RS485 or fiber optics. Modbus output for integrations and Contact ID for connection to CMS (optional). Full remote access of the panel if a TED-151-CL card (Detnov Cloud) is added. CPR certificate EN54-2, EN54-4 and EN54-13. Requires 2 BTD-1207 batteries not included. Dimensions: 430 x 268 x 109 mm.
Color
Black
Device Type
Control Panel
CODE:
09816
4 LOOP ADDRESSABLE CONTROL PANEL CAD-150-4
0.0
In stock
3,302
00
₾
Add to cart
+
−
Addressable fire alarm control panel with 4 loops. Up to of 1.000 addresses (250 addresses per loop: detectors, modules, sounders or manual call points). Self-search and self-diagnosis functions. 250 programmable zones, 6.000 event history logs, free configuration and maintenance software, configuration via USB port, 2 supervised sounder outputs and 2 configurable relay outputs. Graphic LCD display. Auxiliary output of 24V 500mA. Metal box. Multilingual keyboard. Able to be networked (F-Network or S-Network) up to 32 control panels o repeaters via RS485 or fiber optics. Modbus output for integrations and Contact ID for connection to CMS (optional). Full remote access of the panel if a TED-151-CL card (Detnov Cloud) is added. CPR certificate EN54-2, EN54-4 and EN54-13. Requires 2 BTD-1207 batteries not included. Dimensions: 430 x 360 x 120 mm
Color
Black
Device Type
Control Panel
CODE:
10385
ABORT MANUAL CALL POINT PPD-100 - 85311030
0.0
In stock
93
00
₾
Add to cart
+
−
Abort manual call point. Color blue. With test key, surface mount. Protective plastic cover included. Indoor use. Includes resistance of 100 Ohm -2W. Dimensions: 98 x 98 x 48 mm.
Color
Blue
Device Type
Call Point
CODE:
09510
ADDRE. LOOP POWERED SOUNDER w/ FLASH MAD-465-I
0.0
Out of stock
284
00
₾
Out of stock
Addressable loop sounder with beacon and built-in isolator. Low power consumption. 32 tones and 3 configurable volumes (Low, Medium, High). Acoustic power 76 dBA to 117 dBA depending on the selected tone. It takes just one address in the loop. Red color. IP33C. Deep base. CPR certificate EN 54-3 and EN 54-17. Dimensions: 100 x 75 mm
Color
Red
Device Type
Sounder
CODE:
10433
ADDRE. MODULE 1 INPUTS 1 OUTPUTS w/ ISO MAD-421-I
0.0
In stock
156
00
₾
Add to cart
+
−
Addressable monitor and control module with built-in isolator of 1 supervised technical input for the status signaling of equipment that provides NC or NO contact and 1 voltage-free relay output providing C, NO, NC contact. It takes two loop addresses. Direct feed from the loop. LED status indicators. Connection through removable strips up to 2.5mm2 section. Possibility of being installed in DIN rail or flat to wall mounting in box BOX-ONE. Consumption less than 300μA at rest. Red color. Dimensions: 100 x 82 x 23 mm. CPR certificate EN54-18 and EN54-17.
Color
Red
Device Type
Modular
CODE:
09794
ADDRE. MODULE 2 INPUTS 2 OUTPUTS w/ ISO MAD-422-I
0.0
In stock
230
00
₾
Add to cart
+
−
Addressable monitor and control module with built-in isolator of 2 supervised technical inputs for the status signaling of equipment that provide NC or NO contact and 2 voltage-free relay outputs providing two C, NO, NC contacts. It occupies four directions in the loop. Direct feed from the loop. LED status indicators. Connection through removable strips up to 2.5mm2 section. Possibility of being installed in DIN rail or flat to wall mounting in box BOX-ONE. Consumption less than 300μA at rest. Red color. Dimensions: 100 x 82 x 23 mm. CPR certificate EN54-18 and EN54-17.
Color
Red
Device Type
Modular
CODE:
15361
ADDRESS PROGRAMMER PGD-202
0.0
Out of stock
885
00
₾
Out of stock
Hand-held programmer for 200A addressable detectors range and 400 series devices (modules, call points and sounders). Allows the display of the device address, analogue value of the detectors and consecutive address programming. Includes 4 AA batteries.
Color
White
Device Type
Programmer
CODE:
15309
ADDRESSABLE CALL POINT w/ ISO. MAD-451-I
0.0
In stock
142
00
₾
Add to cart
+
−
Addressable manual call point with built-in isolator. LED status indicator and test key. Red color. CPR certificates EN54-11 and EN54-17. Dimensions: 85 x 85 x 55 mm.
Color
Red
Device Type
Call Point
CODE:
09507
ADDRESSABLE HEAT DETECTOR DTD-210A
0.0
Out of stock
78
00
₾
Out of stock
Addressable heat (58°C fixed temperature and thermal rate of rise) detector with built-in isolator, with algorithm verification. Led status indicator and output for remote pilot indicator PAD-10 or buzzer BUD-200. White color. Requires base Z-200 or Z-200-H. Anti-theft system (only with Z-200). CPR certificate EN 54-5 and EN 54-17. Dimensions: 100 x 40 mm.
Color
White
Device Type
Detector
CODE:
09571
ADDRESSABLE HEAT DETECTOR DTD-210A-B
0.0
In stock
114
00
₾
Add to cart
+
−
Addressable heat (58°C fixed temperature and thermal rate of rise) detector, with algorithm verification. Led status indicator and output for remote pilot indicator PAD-10 or buzzer BUD-200. Black color. Allows installation without polarity. Requires base Z-200-B or Z-200-B-H. Anti-theft system (only with Z-200). CPR certificate EN 54-5. Dimensions: 100 x 40 mm.
Color
Black
Device Type
Detector
CODE:
11430
ADDRESSABLE HEAT DETECTOR w/ISOLATOR DTD-210A-I
0.0
In stock
112
00
₾
Add to cart
+
−
Addressable heat (58°C fixed temperature and thermal rate of rise) detector with built-in isolator, with algorithm verification. Led status indicator and output for remote pilot indicator PAD-10 or buzzer BUD-200. White color. Requires base Z-200 or Z-200-H. Anti-theft system (only with Z-200). CPR certificate EN 54-5 and EN 54-17. Dimensions: 100 x 40 mm.
Color
White
Device Type
Detector
CODE:
09503
ADDRESSABLE HEAT&SMOKE DETECTOR DOTD-230A
0.0
In stock
108
00
₾
Add to cart
+
−
Addressable optical & heat detector with built-in isolator, with dirt compensation and algorithm verification. Led status indicator and output for remote pilot indicator PAD-10 or buzzer BUD-200. White color. Requires connection base Z-200 or Z-200-H. Anti-theft system (only with Z-200). CPR certificates EN 54-5, EN 54-7 and EN 54-17. Dimensions: 100 x 40 mm.
Color
White
Device Type
Detector
CODE:
09835
ADDRESSABLE HEAT&SMOKE DETECTOR with b/i ISOLATOR DOTD-230A-I
0.0
In stock
119
00
₾
Add to cart
+
−
Addressable optical & heat detector with built-in isolator, with dirt compensation and algorithm verification. Led status indicator and output for remote pilot indicator PAD-10 or buzzer BUD-200. White color. Requires connection base Z-200 or Z-200-H. Anti-theft system (only with Z-200). CPR certificates EN 54-5, EN 54-7 and EN 54-17. Dimensions: 100 x 40 mm.
Color
White
Device Type
Detector
CODE:
10371
ADDRESSABLE HIGH TEMP DETECTOR DTD-215A
0.0
In stock
89
00
₾
Add to cart
+
−
Addressable high temperature detector (fixed at 78ºC) with built-in isolator, with algorithm verification. Led status indicator and output for remote pilot indicator PAD-10 or buzzer BUD-200. White color. Requires connection base Z-200 or Z-200-H. Anti-theft system (only with Z-200). CPR certificate EN 54-5 and EN 54-17. Dimensions: 100 x 40 mm.
Color
White
Device Type
Detector
CODE:
11431
ADDRESSABLE HIGH TEMP DETECTOR w/ISOLATOR DTD-215A-I
0.0
Out of stock
97
00
₾
Out of stock
Addressable high temperature detector (fixed at 78ºC) with built-in isolator, with algorithm verification. Led status indicator and output for remote pilot indicator PAD-10 or buzzer BUD-200. White color. Requires connection base Z-200 or Z-200-H. Anti-theft system (only with Z-200). CPR certificate EN 54-5 and EN 54-17. Dimensions: 100 x 40 mm.
Color
White
Device Type
Detector
CODE:
09509
ADDRESSABLE MANUAL CALL POINT w/ ISO. MAD-450-I
0.0
In stock
149
00
₾
Add to cart
+
−
Addressable manual call point with built-in isolator. LED status indicator and test key. Red color. CPR certificates EN54-11 and EN54-17. Dimensions: 98 x 98 x 48 mm.
Color
Red
Device Type
Call Point
CODE:
10386
ADDRESSABLE MODULE 1 RELAY OUTPUT MAD-411 MAD-411
0.0
In stock
164
00
₾
Add to cart
+
−
Addressable control module for 1 relay output, provides one contact C, NO, NC. It takes one address in the loop. Fed directly from the loop. LED status indicator. Connection through removable strips up to 2.5mm2 section. Possibility of being installed in DIN rail or flat to wall mounting in box BOX-ONE. Consumption less than 300μA at rest. Non polarity installation. Red color. Dimensions: 100 x 82 x 23 mm. CPR certificate EN54-18.
Color
Red
Device Type
Modular
CODE:
13760
Addressable monitor module of 1 conventional zones MAD-441-I
0.0
In stock
227
00
₾
Add to cart
+
−
Addressable monitor module of 1 conventional zone, allows connection of up to 20 conventional detectors and / or 32 conventional manual call points. Can identify between detector alarm and push button, between the fault by cutting or by short circuit in the zone. It takes one loop address. Requires 24 Vdc auxiliary power. LED status indicator. Connection through removable strips up to 2.5mm2 section. Possibility of being installed in DIN rail or flat to wall mounting in box BOX-ONE. Consumption less than 300μA at rest. Allows installation without polarity. Red color. Dimensions: 100 x 82 x 23 mm. CPR certificate EN54-18.
Color
Red
Device Type
Modular