Detnov

12739
0.0
Out of stock
26000 
Indicator light with buzzer
Device TypeBeacon Fire Alarm System TypeExtinguishing System
09579
0.0
In stock
53800 
+
Conventional fire alarm control panel for 2 zones mounted on ABS plastic housing. Flush mount option. Discriminates between detector alarm and manual call points alarm. Up to 32 detectors per zone. Possibility to connect to PC via USB for complex programming. Integrable to addressable systems directly to the loop. It has 2 configurable supervised sounder outputs (500 mA each output), alarm and fault relay outputs free of voltage, auxiliary 24V output (500 mA maximum consumption), 24V resettable output (500 mA maximum consumption) and 1 programmable external input. TSD100: 4 supervised sounder outputs, TMD-100: Modbus output for integrations, TPLD-100: integration to addressable loop). Tele maintenance and remote control through TED-151-CL card (Detnov Cloud). Multilingual keyboard. CPR certificate EN54-2 ,EN54-4 and EN54-13. Dimensions: 443 x 268 x 109 mm. Requires 2 BTD-1207 batteries (not included).
ColorBlack Device TypeControl Panel
09847
0.0
In stock
57200 
+
Conventional fire alarm control panel for 4 zones mounted on ABS plastic housing. Flush mount option. Discriminates between detector alarm and manual call points alarm. Up to 32 detectors per zone. Possibility to connect to PC via USB for complex programming. Integrable to addressable systems directly to the loop. It has two configurable supervised siren outputs (500 mA each output), alarm and fault relay outputs free of voltage, auxiliary 24V output (500 mA maximum consumption), 24V resettable output (500 mA maximum consumption) and 1 external input programmable. TSD100: 4 supervised siren outputs, TMD-100: Modbus output for integrations, TPLD-100: integration to addressable loop). Tele maintenance and remote control through TED-151-CL card (Detnov Cloud). Multilingual keyboard. CPR certificate EN54-2 ,EN54-4 and EN54-13. Dimensions: 443 x 268 x 109 mm. Requires 2 BTD-1207 batteries (not included).
ColorBlack Device TypeControl Panel
10384
0.0
In stock
46800 
+
Conventional fire alarm control panel for 4 zones mounted on ABS plastic housing. Discriminates between detector alarm and manual call points alarm. Up to 32 detectors per zone. It has 2 configurable supervised sounder outputs (500 mA each output), alarm and fault relay outputs free of voltage, auxiliary 24V output (500 mA maximum consumption), 24V resettable output (500 mA maximum consumption). Sounder output delay configurable on board Multilingual keyboard. CPR certificate EN54-2 and EN54-4. Dimensions: 282 x 240 x 102 mm. Requires 2 BTD-1202 batteries (not included).
ColorBlack Device TypeControl Panel
09769
0.0
In stock
1,81500 
+
Bidirectional repeater for Detnov addressable CAD-150 series. Allows the remote supervision control of control panels networked (F-Network) up to 32 nodes. It shows the same incidences reflected in the control panel. It can be added in ring or bus networks configurations. LCD display and 4 control keys (reset, mute buzzer, mute sounders and activate sounders). Includes RS485 communication card (TRED-150). ABS plastic casing for wall mounting and even prepared to be embedded into it. Requires 230Vac and 2 batteries BTD-1207 (not included). Dimensions: 443 x 268 x 109 mm.
ColorBlack Device TypeRepeater
11681
0.0
In stock
12300 
+
Release manual call point
ColorYellow Device TypeCall Point
10379
0.0
In stock
7100 
+
Indoor alarm sounder. 3 selectable tones. Power at 24Vdc/7mA. IP44. Red color. Acoustic power between 82,5dB. CPR certificate EN54-3. Dimensions: 65 x 90 mm.
ColorRed Device TypeSounder
09580
0.0
In stock
5000 
+
Conventional optical smoke detector. Led status indicator and output for remote pilot indicator PAD-10. White color. Allows installation without polarity. Requires connection base Z-200 or Z-200-H. Anti-theft system (only with Z-200). CPR certificate EN 54-7. Dimensions: 100 x 40 mm.
ColorWhite Device TypeDetector
13898
0.0
In stock
10500 
+
Approved worldwide, Solo aerosols deliver smoke particles to the detector under test replicating conditions of smoke from a fire. Detector manufacturer approved Designed for use with the Solo 330/332 dispensers Compliant with latest aerosol regulations UL Certified
Fire Alarm System TypeAddressable System, Conventional System ManufactureUK
14453
0.0
In stock
78400 
+
Communication card for addressable control panels serie CAD-150. Includes Ethernet port, RS485 output for network connection (S-Network), 2 x RS485 for Modbus integration, RS232 output for serial printer Includes. Includes electric isolation circuit between nodes. 1.000 meters maximum distance between nodes.
Device TypeModular Fire Alarm System TypeAddressable System
14918
0.0
Out of stock
1,98600 
The  Fire Beam Xtra  self-aligns to the centre of the reflector during commissioning and will automatically keep alignment when building movement occurs. This intelligent motorisation will result in fewer false alarms, thereby saving time, resources –and, ultimately– money.
Device TypeDetector
Brand
In Stock