GSM დამცავი მოდული SP131 ანტენით ANT04
Please sign in so that we can notify you about a reply
- Power supply AC 16–18 V or DC 16 – 24 V
- Power consumption (only module) 80 mA idle running
- Up to 150 mA within transmitting
- Backup power supply 12 V / 7 Ah battery
- Battery charging current 0,1-2,0 A
- Power supply for connected security devices Direct 13.6 V voltage between [AUX+] and [COM] contacts, current up to 1.1 A
- GSM modem SIM900 specification GSM EGSM 900 MHz and DCS 1800 MHz
- Power failure thresholds Alternating power supply is lost/restored
- Voltage of the battery has dropped to 11,5 V
- Voltage of the battery has restored to 12,6 V
- ZN terminals (inputs) 8 programmable;
- selectable NC, NO or EOL=2,2 kΩ type;
- Expandable to up to 32 inputs with input expansion modules CZ8
- Various expansion modules Up to 14, including keypads
- PGM terminals (outputs) 4, NO type terminals of the field-effect transistor, able to commutate up to 30 V / 1.5 A between COM terminal
- Control codes Up to 40
- Entry Delay and Exit Delay times 0-255 seconds
- Siren duration 0–9999 seconds
- Communication protocols TCP/IP or UDP/IP over GPRS;
- SMS
- Encoding of messages Contact ID protocol codes
- SMS messages to users Customized text to 5 mobile phones, according to selected event types
- Calls to the user To 2 mobile phones, according to selected event types
- Operating environment From -10 C to 50 C when relative air humidity is 80 % at +20 C
- Dimensions 103 x 71 x 33,5 mm
ბრენდი
Trikdis